EQUIPMENT for ACWS.
Manufacturer: “SCIENTIFIC AND PRODUCTION ENTERPRISE” OZON S “
Automated centralized warning system (territorial or city) (hereinafter – ACWS) in most cases includes a standard set of software and hardware control and notification tools:
- ACWS control panel (main, backup).
Composition:
1) Personal computer running an operating system Windows.
2) Printer.
Provides the ability to print reports on the results of the notification, and is also used to print electronic maps of accidents received from a high-risk facility in the event of an emergency at the facility. Reports are generated in the “Notification Module” software.
3) Modem device universal ПМУ-01 (PMU-01)
Device functions ПМУ-01:
– organization of a communication channel;
– broadcasting of information messages via the communication channel;
– reception from objects of increased danger of information about an emergency situation that has arisen at the object.
ПМУ-01 allows to use 4 lines of fixed telephony and 2 channels of GSM standard in the notification procedure.
The maximum number of ПМУ-01 involved in the ACWS control panel is not limited.
One ПМУ-01, provided that all possible communication channels are used, provides an average notification rate of 12 subscribers per minute.
4) Uninterruptible Power Supply ДБЖ-12 (DBZH-12).
Designed to provide power supply for МУ-01 and other devices. One source allows powering up to three ПМУ-01. The source includes a battery designed to operate for 24 hours in standby mode, and at least an hour in alert mode.
5) Specialized software “Notification Module”, “Detection Module” and “Notification Control Panel”.
- Equipment for automatic interception of radio broadcasting.
It is used if there are on-air or wire broadcasting stations on the territory of the administrative unit.
The MKO-4TR notification control module (hereinafter referred to as the module) is used as such equipment.
The module is designed to intercept broadcasting of an on-air radio station on command from the remote control and broadcast information messages on the air. The module can broadcast pre-prepared messages that are stored in the module’s memory, as well as relay messages received from the console via communication channels in real time.
- Terminal warning devices installed in the premises of social facilities (school and preschool educational institutions, medical institutions, etc.).
As such a device, notification units БO-FM-04 (BO-FM-04) (hereinafter – notification unit) are used. The paging unit is intended for organizing voice messaging indoors with monitoring of listening to information messages.
Thanks to the built-in monitoring function for listening to the message, a receipt is transmitted to the control panel exactly about the fact of listening to information.
- Terminal devices for controlling the existing electric sirens C-40 and C-28, which are on the balance sheet of the administrative unit.
As such a device, notification units БO-FM-04-С (BO-FM-04-С) (hereinafter referred to as the unit) are used. The unit is designed to activate an existing electric siren on command from the remote control. Installed in parallel to the existing electric siren control system, which allows both systems to be operated independently of each other.
-
Terminal warning devices in open areas. The quantities and locations of installation are selected based on the maximum sounding by signals “Attention to all” in places with a massive presence of people.
Terminal warning devices in open areas with autonomous power supply. The БO-FM-05 (BO-FM-05) notification unit (hereinafter referred to as the unit) is used as such a device.
The block is designed to inform in open areas with voice messages and special signals.
It has an autonomous power supply, therefore it does not depend on the power supply.
Terminal warning devices in open areas powered by 220 V. As such a device, notification units based on the MKO-1T notification control module are used.
The unit is designed to inform in open areas by voice and special signals.
- Integration of automated systems for early detection of emergencies and notification (hereinafter referred to as ASEDEN) and local automated centralized warning systems (hereinafter referred to as LASWS) into the ACWS.
For the most effective coverage of an administrative unit by means of notification, the ACWS integrates previously built or created in the future ASEDEN and LASWS – the so-called object notification systems.
In this case, at the command of the ACWS, the ASEDEN and LASWS are activated, thus expanding the notification area.
The concept of equipment control based on the “OZON-O” software and hardware complex consists in transmitting activation commands for pre-formed notification scenarios that are stored in the ASEDEN and LASWS. The command is transmitted from the ACWS console to the ASEDEN and LASWS consoles via a public telecommunications network for fixed-line telephony, mobile communications of the GSM standard or via digital networks (dedicated or Internet with a VPN function).
In turn, each ASEDEN and LASWS panel has its own set of terminal devices, which are activated already at the command of the ASEDEN and LASWS panel.
Thus, the greatest concentration of control nodes is achieved and the time for activating terminal equipment from the side ACWS.